DR (Digital Registry) Meter
The DR meter carries with it new innovative technology in a digital
meter. Our new meter is precision balanced, lightweight and
ergonomically designed. Simple, accurate and efficient, this meter
combines new features with proven oval gear technology.
Features
- No field calibration required: Precision machined aluminum
die-cast fluid chamber maintains the tight tolerances required for
repeatable accuracy. Each meter is individually tested for
performance and accuracy which guarantees precise dispensing regardless
of fluid viscosity, system pressure or changes in outside temperature.
- Meter housing: unique totally encased polycarbonate housing with TP
Elastomer over mold provides superb impact resistance while isolating
the electronic register module (ERC) from the environment which
provides an airtight seal with the meter body.
- Sealed battery compartment: battery clips are mounted directly on
the ERC, no cables for battery contact, which ensures protection against
the environment, impact, or vibrations.
- Low power consumption: ERC with auto-sleep function for improved battery life.
- Trip mode function: resettable totalizer function can operate as an economical, simple fluid inventory control system.
- Non-resettable totalizer function: shows total fluid flow through
the meter from day one and is unaffected by low or dead batteries.
- All new handle: aluminum body with lightweight ergonomic soft grip handle for comfort and precision balance.
- Unique ¼ turn manual tip: effective and very fast, high flow, no splash and very easy to use.
- Flange coupling at the control valve: eliminates the use of
connection adapters which can become loose, providing superior
integration of the meter and handle.
- Swivel cover protects automobiles from nicks and scratches.
- Large ported swivel: for comfort even at high pressures, includes durable inlet filter which protects meter from debris.
- Trigger lock button: prevents accidental dispense and also allows the gun to be locked in the open position.
- Affordable repairability: ERC can be changed easily.
Specifications
Units of measure
(in 0.01 increments) |
Gallon, quart, pint or liter |
Accuracy |
+/- 0.5% of reading (lubricating oils) |
Flow range |
0.26-8 gal/m (1-30 l/m) |
Max pressure |
1,450 psi (100 bar) |
Swivel inlet |
1/2” NPT (F) |
Dispense Nozzle OD |
Auto=0.605″
Manual 1/4 turn for Oil =0.705″
Manual 1/4 turn for ATF =0.315″
Verify the ID of ATF fill port for compatibility |
Operating temp |
14ºF-160ºF (-10ºC-70ºC) |
Battery |
2 x 1.5 v alkaline “AAA” |
Weight |
3.2 Lbs (1.55 kg) (meter) |
Compatible fluids |
Lubricants (up to SAE 140), ATF, Anti-freeze (Glycol), and Anti-freeze water solution |
Wetted materials |
Liquid Crystal Polymer (LCP), Aluminum, Buna-N™, Zinc Plated Steel, Stainless Steel, Neodymium, and Brass |